Строка 1: |
Строка 1: |
| + | = IPCs = |
| + | Sometimes, you will need to repair synthetics other than Cyborgs, such as IPCs. The procedures for repairing an IPC are quite different from that of cyborgs, and are as follows: |
| | | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | === Exterior repair === |
| + | |
| + | In the case that any damage is only external (Anything less than "Severe" or "A lot of"), damage can be repaired. |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | For dents: |
| + | # [[File:WeldingHelmet.png]] Equip a welding helmet on your head. |
| + | # [[File:Welderon.gif]] Place a welder in your hand, click on it while it's in your hand to light it, target the affected organ and then click on the IPC. |
| + | |
| + | For burns: |
| + | # [[File:CableCoils.png]] Target the affected organ and click on the IPC with a cable coil. |
| + | |
| + | </div></div> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | === Advanced interior repair === |
| + | |
| + | IPCs possess their own set of internal organs, the locations and identities of which are as follows (Organs with their name in bold are vital - removing it will kill the IPC!): |
| + | # '''Microbattery''' - chest |
| + | # '''Optical sensor''' - head |
| + | # '''IPC identification tag''' - lower body |
| + | # '''Positronic brain''' - head (NOTE: Removing this will only kill the IPC chassis, not the posibrain itself. The brain will function like a normal posibrain.) |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | ==== Organ repair ==== |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | While targeting the organ's parent limb: |
| + | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. |
| + | # [[File:Nanopaste.png]] [[File:Screwdriver tool.png]] Mend the damage to the organ using nanopaste or a screwdriver. |
| + | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. |
| + | |
| + | </div></div> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | ==== Organ removal ==== |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | While targeting the organ's parent limb: |
| + | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. |
| + | # [[File:Multitool.png]] Decouple the target organ (you can choose if there are multiple) using a multitool. ''NOTE: It may take multiple clicks before it works.'' |
| + | # [[File:Hemostat.png]] Remove the target organ with the hemostat |
| + | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. |
| + | |
| + | </div></div> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | ==== Organ attachment ==== |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | While targeting the organ's parent limb: |
| + | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. |
| + | # Insert the organ by clicking on the IPC with it in your hand. |
| + | # [[File:Screwdriver tool.png]] Reattach the target organ using a screwdriver. |
| + | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. |
| + | |
| + | </div></div> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | ==== Positronic brain installation ==== |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | While targeting the head: |
| + | # [[File:Screwdriver tool.png]] Open the head's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. |
| + | # Install the [[Positronic Brain]] by clicking on the IPC with it in your hand. |
| + | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. |
| + | |
| + | </div></div> |
| + | |
| + | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> |
| + | ==== IPC revival ==== |
| + | <div class="mw-collapsible-content"> |
| + | |
| + | IPCs can be revived much like their biological counterparts, as follows: |
| + | While targeting the chest: |
| + | # [[File:Screwdriver tool.png]] Open the chest's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. |
| + | # [[File:Multitool.png]] Decouple either the [[Positronic brain]] or the cell using a multitool. |
| + | # [[File:Hemostat.png]] Remove the chosen organ with the hemostat |
| + | # [[File:Crowbar.png]] (If chest was damaged) Close and secure the hatch using a crowbar. |
| + | # [[File:CableCoils.png]]|[[File:Welderon.gif]] Repair the IPC chassis (at least until it wouldn't immediately die if revived). |
| + | # [[File:Screwdriver tool.png]] (If chest was damaged) Open the chest's hatch using a screwdriver. |
| + | # [[File:Crowbar.png]] (If chest was damaged) Pry open the hatch using a crowbar. |
| + | # Insert the chosen organ by clicking on the IPC with it in your hand. |
| + | # [[File:Screwdriver tool.png]] (Cell only) reattach the chosen organ using a screwdriver |
| + | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. |
| + | |
| + | </div></div></div></div> |