Обсуждение участника:DosiOzborn

Материал из Chaotic Onyx
Перейти к навигацииПерейти к поиску

IPCs

Sometimes, you will need to repair synthetics other than Cyborgs, such as IPCs. The procedures for repairing an IPC are quite different from that of cyborgs, and are as follows:

Exterior repair

In the case that any damage is only external (Anything less than "Severe" or "A lot of"), damage can be repaired.

For dents:

  1. WeldingHelmet.png Equip a welding helmet on your head.
  2. Welderon.gif Place a welder in your hand, click on it while it's in your hand to light it, target the affected organ and then click on the IPC.

For burns:

  1. CableCoils.png Target the affected organ and click on the IPC with a cable coil.

Advanced interior repair

IPCs possess their own set of internal organs, the locations and identities of which are as follows (Organs with their name in bold are vital - removing it will kill the IPC!):

  1. Microbattery - chest
  2. Optical sensor - head
  3. IPC identification tag - lower body
  4. Positronic brain - head (NOTE: Removing this will only kill the IPC chassis, not the posibrain itself. The brain will function like a normal posibrain.)

Organ repair

While targeting the organ's parent limb:

  1. Screwdriver tool.png Open the limb's hatch using a screwdriver.
  2. Crowbar.png Pry open the hatch using a crowbar.
  3. Nanopaste.png Screwdriver tool.png Mend the damage to the organ using nanopaste or a screwdriver.
  4. Crowbar.png Close and secure the hatch using a crowbar.

Organ removal

While targeting the organ's parent limb:

  1. Screwdriver tool.png Open the limb's hatch using a screwdriver.
  2. Crowbar.png Pry open the hatch using a crowbar.
  3. Multitool.png Decouple the target organ (you can choose if there are multiple) using a multitool. NOTE: It may take multiple clicks before it works.
  4. Hemostat.png Remove the target organ with the hemostat
  5. Crowbar.png Close and secure the hatch using a crowbar.

Organ attachment

While targeting the organ's parent limb:

  1. Screwdriver tool.png Open the limb's hatch using a screwdriver.
  2. Crowbar.png Pry open the hatch using a crowbar.
  3. Insert the organ by clicking on the IPC with it in your hand.
  4. Screwdriver tool.png Reattach the target organ using a screwdriver.
  5. Crowbar.png Close and secure the hatch using a crowbar.

Positronic brain installation

While targeting the head:

  1. Screwdriver tool.png Open the head's hatch using a screwdriver.
  2. Crowbar.png Pry open the hatch using a crowbar.
  3. Install the Positronic Brain by clicking on the IPC with it in your hand.
  4. Crowbar.png Close and secure the hatch using a crowbar.

IPC revival

IPCs can be revived much like their biological counterparts, as follows: While targeting the chest:

  1. Screwdriver tool.png Open the chest's hatch using a screwdriver.
  2. Crowbar.png Pry open the hatch using a crowbar.
  3. Multitool.png Decouple either the Positronic brain or the cell using a multitool.
  4. Hemostat.png Remove the chosen organ with the hemostat
  5. Crowbar.png (If chest was damaged) Close and secure the hatch using a crowbar.
  6. CableCoils.png|Welderon.gif Repair the IPC chassis (at least until it wouldn't immediately die if revived).
  7. Screwdriver tool.png (If chest was damaged) Open the chest's hatch using a screwdriver.
  8. Crowbar.png (If chest was damaged) Pry open the hatch using a crowbar.
  9. Insert the chosen organ by clicking on the IPC with it in your hand.
  10. Screwdriver tool.png (Cell only) reattach the chosen organ using a screwdriver
  11. Crowbar.png Close and secure the hatch using a crowbar.