Обсуждение участника:DosiOzborn: различия между версиями
Материал из Chaotic Onyx
Перейти к навигацииПерейти к поиску (Полностью удалено содержимое страницы) |
|||
Строка 1: | Строка 1: | ||
+ | = IPCs = | ||
+ | Sometimes, you will need to repair synthetics other than Cyborgs, such as IPCs. The procedures for repairing an IPC are quite different from that of cyborgs, and are as follows: | ||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | === Exterior repair === | ||
+ | |||
+ | In the case that any damage is only external (Anything less than "Severe" or "A lot of"), damage can be repaired. | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | For dents: | ||
+ | # [[File:WeldingHelmet.png]] Equip a welding helmet on your head. | ||
+ | # [[File:Welderon.gif]] Place a welder in your hand, click on it while it's in your hand to light it, target the affected organ and then click on the IPC. | ||
+ | |||
+ | For burns: | ||
+ | # [[File:CableCoils.png]] Target the affected organ and click on the IPC with a cable coil. | ||
+ | |||
+ | </div></div> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | === Advanced interior repair === | ||
+ | |||
+ | IPCs possess their own set of internal organs, the locations and identities of which are as follows (Organs with their name in bold are vital - removing it will kill the IPC!): | ||
+ | # '''Microbattery''' - chest | ||
+ | # '''Optical sensor''' - head | ||
+ | # '''IPC identification tag''' - lower body | ||
+ | # '''Positronic brain''' - head (NOTE: Removing this will only kill the IPC chassis, not the posibrain itself. The brain will function like a normal posibrain.) | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | ==== Organ repair ==== | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | While targeting the organ's parent limb: | ||
+ | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. | ||
+ | # [[File:Nanopaste.png]] [[File:Screwdriver tool.png]] Mend the damage to the organ using nanopaste or a screwdriver. | ||
+ | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. | ||
+ | |||
+ | </div></div> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | ==== Organ removal ==== | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | While targeting the organ's parent limb: | ||
+ | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. | ||
+ | # [[File:Multitool.png]] Decouple the target organ (you can choose if there are multiple) using a multitool. ''NOTE: It may take multiple clicks before it works.'' | ||
+ | # [[File:Hemostat.png]] Remove the target organ with the hemostat | ||
+ | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. | ||
+ | |||
+ | </div></div> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | ==== Organ attachment ==== | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | While targeting the organ's parent limb: | ||
+ | # [[File:Screwdriver tool.png]] Open the limb's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. | ||
+ | # Insert the organ by clicking on the IPC with it in your hand. | ||
+ | # [[File:Screwdriver tool.png]] Reattach the target organ using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. | ||
+ | |||
+ | </div></div> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | ==== Positronic brain installation ==== | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | While targeting the head: | ||
+ | # [[File:Screwdriver tool.png]] Open the head's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. | ||
+ | # Install the [[Positronic Brain]] by clicking on the IPC with it in your hand. | ||
+ | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. | ||
+ | |||
+ | </div></div> | ||
+ | |||
+ | <div class="toccolours mw-collapsible mw-collapsed" style="width:99%"> | ||
+ | ==== IPC revival ==== | ||
+ | <div class="mw-collapsible-content"> | ||
+ | |||
+ | IPCs can be revived much like their biological counterparts, as follows: | ||
+ | While targeting the chest: | ||
+ | # [[File:Screwdriver tool.png]] Open the chest's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] Pry open the hatch using a crowbar. | ||
+ | # [[File:Multitool.png]] Decouple either the [[Positronic brain]] or the cell using a multitool. | ||
+ | # [[File:Hemostat.png]] Remove the chosen organ with the hemostat | ||
+ | # [[File:Crowbar.png]] (If chest was damaged) Close and secure the hatch using a crowbar. | ||
+ | # [[File:CableCoils.png]]|[[File:Welderon.gif]] Repair the IPC chassis (at least until it wouldn't immediately die if revived). | ||
+ | # [[File:Screwdriver tool.png]] (If chest was damaged) Open the chest's hatch using a screwdriver. | ||
+ | # [[File:Crowbar.png]] (If chest was damaged) Pry open the hatch using a crowbar. | ||
+ | # Insert the chosen organ by clicking on the IPC with it in your hand. | ||
+ | # [[File:Screwdriver tool.png]] (Cell only) reattach the chosen organ using a screwdriver | ||
+ | # [[File:Crowbar.png]] Close and secure the hatch using a crowbar. | ||
+ | |||
+ | </div></div></div></div> |
Версия от 13:07, 23 октября 2017
IPCs
Sometimes, you will need to repair synthetics other than Cyborgs, such as IPCs. The procedures for repairing an IPC are quite different from that of cyborgs, and are as follows:
Exterior repair
In the case that any damage is only external (Anything less than "Severe" or "A lot of"), damage can be repaired.
Advanced interior repair
IPCs possess their own set of internal organs, the locations and identities of which are as follows (Organs with their name in bold are vital - removing it will kill the IPC!):
- Microbattery - chest
- Optical sensor - head
- IPC identification tag - lower body
- Positronic brain - head (NOTE: Removing this will only kill the IPC chassis, not the posibrain itself. The brain will function like a normal posibrain.)
Organ repair
Organ removal
While targeting the organ's parent limb:
Organ attachment
Positronic brain installation
While targeting the head:
- Open the head's hatch using a screwdriver.
- Pry open the hatch using a crowbar.
- Install the Positronic Brain by clicking on the IPC with it in your hand.
- Close and secure the hatch using a crowbar.
IPC revival
IPCs can be revived much like their biological counterparts, as follows: While targeting the chest:
- Open the chest's hatch using a screwdriver.
- Pry open the hatch using a crowbar.
- Decouple either the Positronic brain or the cell using a multitool.
- Remove the chosen organ with the hemostat
- (If chest was damaged) Close and secure the hatch using a crowbar.
- | Repair the IPC chassis (at least until it wouldn't immediately die if revived).
- (If chest was damaged) Open the chest's hatch using a screwdriver.
- (If chest was damaged) Pry open the hatch using a crowbar.
- Insert the chosen organ by clicking on the IPC with it in your hand.
- (Cell only) reattach the chosen organ using a screwdriver
- Close and secure the hatch using a crowbar.